Solid State Relay SSR to AC 80A 3‑32VDC Input 480VAC Output VSR8‑80DA48Z









الوصف
Feature: 1. ISOLATION AND INTERFACE: Optical isolation is used between the input and output circuits, with control signals and TTL logic interfaces 2. FAST AND EFFICIENT: Transistor output, possess small on voltage drop, fast switching speed. LED indicator show the working status at a 3. CORROSION RESISTANT MATERIAL: Solid state relay adopt epoxy resin encapsulation, corrosion resistant and shockproof, support 4. APPLICABLE SCENARIO: SSR is mainly used in industrial automation, weak current isolation control, strong current isolation control and all kinds of high power electrical equipment. Such as motor, solenoid valve, electromagnetic vibrator, battery charging and discharging switch . EASY TO INSTALL AND USE: This solid state relay is designed for easy installation and use. Simply connect your control and load, and enjoy power switching Specification: Item Type: Solid State Relay Model: VSR8-80DA48Z Input: 3-32VDC Output: 80A 480VAC Load Current Range: 0.1 to 80Arms
Current 10mSec(maximum): 200% Load Voltage Range: 60Vd-1200VDC On State Voltage Drop: ≤0.~4.6 Off State Voltage: 60V, 80V, 250V, 400V, 600V, 2900V, 1200V Overvoltage : Transient Voltage: 80V, 180V, 470V, 1000V Switching Characteristics: Mos or IGBT solid state non contact switching characteristics Dielectric Strength, Input To Output(50/60Hz): 2500Vrms Dielectric Strength, Input or Output Base(50/60 Hz): 2500Vrms Minimum Insulation Resistance(at 500VDC): 10Ω Load Current Safety Factor: Resistive load 2.-3 times, inductive load 3-6 times Ambient Operating Temperature Range: -30 to 80℃ Storage Ambient Temperature Range: -30 to 100℃ Humidity Complies With IEC60068-2-78: 95% LED Input Status Indicator: Red Package List: 1 x Solid State Relay Note: 1. The heat generated by the of the relay needs to be dissipated through the baseplate. that the baseplate of the relay is in close contact with the heat sink, securely installed, and the contact should be equipped with a thermal pad or coated with thermal silicon grease. 2. The relay terminals should be securely connected. Loose connections can cause abnormal heating and damage to the product. The recommended installation torsion for M4 terminals is (1.2~2.0) N·m, and for M5 terminals is (2~3) N·m. 3. When the operating environment temperature of the product is high, please refer to the temperature curve for derating. Safety Warning: 1. The side and baseplate of the product will become hot during use. Please wait for it to cool down before touching. 2. Before installing or using this product, make sure to disconnect all power sources. 3. Please check all connections before turning on the power.